The Twist lock, bayonet style, quick disconnect inline installation assembly allows for rapid insertion and removal for inline applications.
The 1" Turtle Tough Twist Lock Receptacle fits together with any suitable mating 1" Turtle Tough Twist Lock Sensor. It is designed to interface with a 1" FNPT pipe tee fitting.
The twist lock receptacle material of construction is either KYNAR (1"MNPT-TWISTLOCK-KYNAR-SS) for use up to 50 psig or PEEK (1"MNPT-TWISTLOCK-PEEK-HASTC) for use up to 100 psig.
The O-ring material of construction is Viton-75 standard; CV75, Simriz 485 & Kalrez 4079 are optional.
Twist lock sensor bodies can be made from RYTON, RADEL or PEEK. Please consult sensor specification. The max insertion depth past 1" MNPT threads on twist lock receptacle is 0.8" to 1.0" inches for twist lock sensor without protective tines and 0.7" max insertion depth for twist lock sensors with optional protective.
Please carefully check the recommend maximum temperature and pressure rating of your sensor prior to installation.
The challenge A large chicken farm had an issue with pH sensor life. The OEM sensors were only lasting 1-2 weeks in the waste water treatment and water discharge monitoring locations.